mic, sprinkler pipe, schedule 10
Sprinklers and Sprinkler Systems  
 
Sprinkler System

 

 

 

 
Welcome to magicsprinkler.com where you can find all things related to the world of sprinklers, sprinkler systems, and lawn care maintenance. Let's face it, there are a lot of sites out there with a lot of garbage about sprinklers and few with detail information about what can make your sprinkler system run at an optimized level. Are you curious about sprink lsystems, or just want to learn how to be fix your own sprinklers? Well then you've come to the right place at magicsprinkler.com
  
  
Sprinkler GPM

02/07/12

As we saw previously, the flow rate in gallons per minute (GPM) of each sprinkler head is determined by the nozzle installed in the head. It is necessary to know the GPM for each head in order to determine which heads will be connected to each valve and in order to determine the size of each pipe in the sprinkler system.

You will probably need to dig up the sprinkler manufacturer's literature again. In the literature the manufacturer shows different GPM and radius information for each sprinkler nozzle based on the operating pressure (PSI). Now we can use that information to find the GPM for each sprinkler head. First, determine what the SPACING is between each head and the others around it. Next, look for the radius closest to that spacing and use the corresponding GPM as the flow for the head.

Write down on your plan the GPM for each sprinkler next to the sprinkler symbol.


Hint: If you're a tutorial supporter you will find the GPM and radius data for many of the popular sprinklers in the Bonus Section.

Example: You note that a spray type head on your plan is a 1/2 circle pattern and the distance to the 3 closest adjacent heads are 13 feet, 12 ft., and 14 ft.. So the spacing for this head is 14 ft. (the highest of the 3). Looking at the manufacturer's literature you note that a radius of 14 ft. for the 1/2 circle nozzle in this sprinkler requires a pressure of 25 PSI and a flow of 1.65 GPM. Write down the flow of 1.65 GPM next to the sprinkler head on your drawing. You then repeat this procedure for each sprinkler head on your drawing.

 

  

mic, sprinkler pipe, schedule 10

Top mic, sprinkler pipe, schedule 10 Resources

Our Top mic, sprinkler pipe, schedule 10 Resource


Magic Sprinklers, Sprinkler Systems, and Sprinkler Parts

Fix your own sprinkler systems fast and easy, or have a qualified sprinkler company repair your sprinkler system.

Click Here Right Now

More mic, sprinkler pipe, schedule 10 Resources


The True Threat Of A High Corrosion Problem To A Fire Sprinkler Line
... lead to an MIC condition. A fire sprinkler system bringing in ... far more sprinkler failures occur today due to the common use of thin wall schedule 10 pipe. Schedule 10 ...


BlazeMaster® fire sprinkler systems
Your browser does not support script. global producer of specialty chemicals ... Immune to Microbiologically Influenced Corrosion (MIC) Corrosion-free in salt ... product name "CPVC Sprinkler Pipe" or "CPVC Sprinkler Fitting." ... nominal 2 in. x 10 in. or nominal 2 in ...


Corrosion Engineering
... sprinkler and condenser water systems - often with disastrous results. 8 Year Old Schedule 10 Condenser Water Pipe ... influenced corrosion (MIC) problem, repeated sterilization ...


Features Item : Fire Protection Piping: How PME Readers Do It
When it comes to fire protection systems, our readers have definite opinions on materials selection, joining methods, and installation. ... products with thinner pipe walls than Schedule 10 that have been listed by UL specifically for fire sprinkler systems ... corrosion process, in particular to prevent MIC. ABF has had ...


Economical, Efficient Protection
Buildings.com The Commercial Buildings Industry Source ... sprinkler systems also weigh substantially less – CPVC pipe weighs approximately one-sixth the weight of steel (Schedule 10 ... Influenced Corrosion (MIC). CPVC pipe and fittings are ...


ABF II Sprinkler Pipe Coating - Allied Tube and Conduit - Tyco Electrical and Metal Products
Advanced MIC protection coating designed to resist or reduce Microbial Colonization. Dyna Thread, Dyna Flow, XL, and BLT are treated with ABF II (certain sizes restricted). ... Lightwall Threadable Pipe. Allied Schedule 10 and Schedule 40. ABF II Coating. Sprinkler Pipe Spec ... and preventing the onset of MIC upon installation and the first 25 ...


Picture Gallery
... Created by either a corrosion cell or an MIC condition, high wall loss is typically found under interior ... however, identified thin wall schedule 10 sprinkler pipe used in some areas ...


Features Item : Forecasting the Lifespan of a Sprinkler System
The quality of water that flows through sprinkler piping can have a limiting effect on the lifespan of the system. ... to Schedule 10, dyna-thread, SuperFlo, XL, dyna-flow, dyna-light or any of the other thinwall pipe options available ... causes of MIC in sprinkler systems is scarce ...


Fire Sprinkler Testing Article.
... far more sprinkler. failures occur today due to the common use. of thin wall schedule 10 pipe. Schedule 10 ... product of MIC and the source of sprinkler. failures, rust ...


Sprinkler Pipe - Allied Tube and Conduit - Tyco Electrical and Metal Products
Engineered sprinkler pipe offerings, well established and recognized in today's market. Allied sprinkler pipe is the first product to offer advanced MIC prevention with our ABF II coating. ... lightwall sprinkler pipe with hydraulics superior to Schedule-10. ... Schedule 10 and Schedule 40. Fully Listed and FM Approved Sprinkler Pipe. ABF II Coating. Advanced MIC ...


MIC Article 2
... pipe and can break off into pieces that could plug a sprinkler. In recent years the industry has recognized and begun to focus on MIC ... less than 10-year-old ...


The Many Corrosion Factors Affecting A Fire Sprinkler System
The most critical piping system for any building property or plant operation is unquestionably the fire sprinkler service. ... sprinkler service, or higher depending upon pipe diameter, pressure, and construction. For 8 in. schedule 10 steel pipe ... a high loss MIC condition develop having ...


Return Previous Next Contents
... MIC) when the. First Sprinkler System is first installed. When you specify Schedule-10/Schedule-40 sprinkler pipe you ... separate approvals, Schedule-10/Schedule-40 gives ...


Corrosion Gallery
... Created by either a corrosion cell or an MIC condition, high wall loss is typically found under interior ... however, identified thin wall schedule 10 sprinkler pipe used in some areas ...


MIC Remediation & Mitigation in FPS:
... thin-walled pipe (schedule-10). Neither are long-term assets if MIC is ... microbiologically influenced corrosion, MIC, fire sprinkler systems, remediation, mitigation, tubercles ...


Consulting-Specifying Engineer - Attack of the Metal-Munching Microbes
... recently, MIC has been implicated in sprinkler pipe failures ... MIC is suspected, heavier gauge pipe, such as Schedule 40, is suggested in place of the more common Schedule 10 ...


Beginning Fire Sprinkler System Planning School
... Technical Info. MIC Information. Recall Page ... Schedule: 2005 Schedule. Jan. 10 - 21, 2005 ... the importance of sprinkler specifications, types of pipe, hangers, fittings, flow tests ...


Features Item : Microbially Influenced Corrosion of Sprinkler Piping
Understanding MIC and its causes is the key to preventing fire protection system failure. ... MIC represents a growing problem for the fire protection industry. The application of thinner-walled piping (e.g., Schedule 10 ... Fire Sprinkler. Fire Protection: Sprinklers, Pipe and ...


S. STEVEN CARL - H.E.R.C. PRODUCTS - (HERC.OB): 00-07-10
THE WALL STREET TRANSCRIPT. Questioning Market Leaders For Long Term Investors. S. STEVEN CARL - H.E.R.C. PRODUCTS - (HERC.OB) CEO Interview - published 07/10/00. DOCUMENT # KAC602. S. ... customers from other pipe cleaning markets began ... the sprinkler pipeline systems through their facilities, discovering MIC in most ...


Technical Articles: Water Velocity: It's Impact on Accuracy of Hydraulic Calculations
... indicated in the Sprinkler handbook new steel pipe actually has a ... the material, both steel (schedule 40) and copper (type M ... for 1-inch pipe at 10 ft/s which ...


NOTE: Please contact us right away if you'd like to make any changes to your listing.