02/07/12
Seasonal maintenance
* At least twice a year, in the early spring and mid summer, inspect the operation
of every sprinkler to see that it is aimed in the right direction and that the
spray pattern is not blocked. If you don't do this you may find that the stubborn
spot in your lawn is due to a blocked sprinkler, not poor soil or too much sun!
* Observe the area around the sprinklers and investigate if you find an area
that is constantly wet. To figure out if you have a leak, read your water meter
when you go to bed, and again when you get up. This should tell you if you have
a significant leak. Look for the little triangle which spins around on the meter
to check for very small leaks. Be sure to turn off your ice maker if you have
one or you'll see a measurable amount of water being used even without opening
a faucet!
System won't water
* Check to see if the controller has power. If it's a mechanical controller,
you may be able to hear the clock motor running, or observe the program dials
moving over a period of several hours. You can verify the outlet supplying the
controller is on by plugging a light in the outlet. If the controller has power,
see if the valves are getting a signal to turn on. This is best done with a
volt meter. Cycle the controller through a manual program and observe the valve
connections to see if power is being provided to each valve.
* See if the water supply to the system is on. Find the shut off valve and backflow
preventer. Make sure the shut off valve is open (rotate the handle counterclockwise
for a gate or globe valve, or turn the handle in line with the pipe for a ball
valve. Make sure the isolation valves at either end of the backflow preventer
are turned on. If you have a master electric valve, make sure it is getting
a signal and that it's flow control is not turned too low.
* Find the master electric valve if you have one. Most systems don't have one.
To see if you do, look for a wire connected to the "pump start" or
"master" post beside the valve connections in the controller case.
If you have a wire attached to this post and you do not have a pump supplying
your system, then you have a master valve. They are usually installed just after
the backflow preventer. Manually activate the master valve and see if the system
begins to operate properly. If so, you have a bad master valve solenoid or a
bad master valve wire.
* If you have verified the controller is sending a signal and you have the supply
valves on, you may have a bad wire. Have you been digging in the yard since
the last time the system watered? If one valve is having trouble, the control
wire to that valve may be severed. If all valves are not operating, you may
have a bad ground wire. Run a piece of wire straight from the controller to
the valve to replace the hot wire. If that valve still doesn't work, run the
new wire to the problem valve to replace the common wire. If you determine you
have a bad wire, replace it. It will be a pain, but unless you can find the
break and fix it, the whole wire will need to be replaced.
* You can trace a wire to locate a broken spot or to locate a valve by using
a valve finder. You can rent one at most commercial irrigation houses or at
a good tool rental store. A pipe finder can also be used. These tools are something
like a metal detector and consist of an antennae you use to follow the wire.
Don't resort to this unless all the other options have failed.
Water won't shut off
* Trapped debris can cause a valve to stay on. This is usually the cause of
this problem if recent repairs have been performed, or if the system was just
installed. Unscrew the top from the valve and carefully remove the diaphragm
and inspect it for debris or damage. Wipe the seal and reinstall it. Be careful
not to lose the solenoid plunger or other parts that sometime want to escape.
* If the bleed hole in the diaphragm (filter in a Rain Bird valve) is plugged,
the valve will not close because the debris prevents pressure from building
in the upper chamber behind the diaphragm.
* The controller may be sending an instruction to the valve to turn on. Try
resetting the watering time.
* Try tightening the solenoid (if it's a Rain Bird valve in particular) or the
bleed screw.
* If the system was just turned it on, it's possible the valve hasn't had time
to build a seal. Try turning on the water to the main and wait ten or fifteen
seconds. If it seals, then all is well.
* The timer may be set incorrectly, telling the valve to turn on at an unexpected
time, or the controller may be defective (a power surge can cause this) and
is telling the station to water.
* The solenoid may be dirty, remove and clean it, then reinstall the soleniod.
A new "spring" or wet spot has formed in your yard
* If the spot is near a sprinkler that is one of the lowest sprinklers in
the station, you may have a leaky valve.
* You may have a broken pipe or fitting. They are both pretty easy to fix. Dig
up enough of the pipe around the break to give you room to work, and to bend
the pipe enough to insert a new piece attached to couplings.
* The diaphragm may be dirty. Open the valve and clean the diaphragm.
* The seal at the bottom of the solenoid may be damaged or installed improperly.
Inspect the seal at the bottom of the solenoid (o-ring on a Rain Bird valve)
and re-install the solenoid.
* The diaphragm may be damaged or has a hole in it
* The solenoid may be dirty, remove and clean it, then reinstall the soleniod.
* If water is leaking from the valve bonnet, tighten the screws around the edge
of the bonnet (valve top).
Brown spot in yard
* You may have a plugged sprinkler nozzle. Turn on the station and see if
the water sprays out of the nozzle normally. If the radius is too small, try
opening up the screw in the top of the nozzle to increase the flow or break
up any trapped debris. You may need to trade out a nozzle with one of a larger
arc or radius to get better coverage.
* If the whole station is affected, the station control wire may be broken or
disconnected in the controller box.
Controller won't operate
* Make sure the controller has power and is grounded properly. If the power
is OK, it's possible the controller has experienced a power surge. Try resetting
the controller by turning off the power (unplugging it) AND removing the backup
battery! We've seen controllers that have to be powered down for a half hour
before they operate normally. If this happens, it is usually a very infrequent
situation.
| | | |
| |
Automatic Sprinklers on eBay
eBay offers great deals on items related to Automatic Sprinklers. ... 1928 Automatic 165' Sprinkler head, ends Jul-5 12:01 am PDT ... Automatic Sprinkler Systems Handbook (1987), ends Jul-5 6:50 am ... RAIN BIRD 1" AUTOMATIC SPRINKLER VALVE (NEW ...
Automatic Sprinklers
... This is why we offer a wide range of extinguishing systems, concentrated on automatic sprinklers. ... down below different categories of automatic sprinklers that can be installed in ...
++ Automatic Sprinklers - FirstDirectory.com ++
... Automatic Sprinklers. Automatic Sprinklers. Active Fire Protection - Penkridge ...
Reliable Automatic Sprinkler Co. -- Taking You Into The 21st Century & Beyond!
Home. What's New. Overseas. Product Catalog. Technical Information. Translated information. Employment Opportunities
Automatic Sprinklers
303.776.7991. Automatic Sprinkler Systems. Let us install an automatic sprinkler system for you. Our specialists will come to your home and measure out your property.
Vermont Irrigation Automatic Underground Lawn Sprinklers
Vermont Irrigation Automatic Underground Lawn Sprinklers for commercial, residential, and garden applications. ... We specialize in custom designed automatic sprinklers for commercial, residential, and garden applications ... be a time-consuming chore. That's why automatic sprinklers are so popular ...
Victaulic - FireLock Automatic Sprinklers
Victaulic offers a complete line FireLock sprinklers to meet all of your fire protection system needs. ... / FireLock Automatic Sprinklers. FireLock Automatic Sprinklers. FireLock Automatic Sprinklers. Victaulic FireLock Automatic Sprinklers keep it simple ...
Automatic Sprinklers -- at Shopping.com
Find, compare and buy Automatic Sprinklers and other Home and Garden products. Read product reviews and compare prices with tax and shipping.
Company Profile: Blackhawk Automatic Sprinklers Inc.
Profile Prices: $29.95 -- Company Name: Blackhawk Automatic Sprinklers Inc. -- Revenue, executive contact info, subsidiaries, news & more. Access all 500K companies: $49.95/month.
British Automatic Sprinkler Association
The British Automatic Sprinkler Association, founded in 1974, is the largest and most influential trade organisation in its field.
Automatic Sprinkler Design
Installers of Automatic Sprinklers, Fire Hydrants, Hosereels, Extinguishers, Piping Contractors and Fire Alarm Systems etc. in South Africa. A registered A.S.I.B. company.
Automatic Sprinklers
Page Title: Automatic Sprinklers. Back | Up | Next. Web. www.tpub.com. Information Categories ... that indicate the need for maintenance for automatic sprinklers include the following: . Mechanical injury such as ...
Central States Automatic Sprinklers
... Central States Automatic Sprinklers, Inc. 13740 South California Avenue, Blue Island, IL 60406 ...
UL | Automatic Sprinklers
UL has the ability to test and List sprinklers to the requirements of the Standards for Automatic Sprinklers for Fire-Protection Services, UL 199, and Early Suppression-Fast Response Sprinklers, UL 1767. ... has been testing and certifying automatic sprinklers for more than 100 years ...
Automatic Sprinklers
Automatic Sprinklers. DS1000. Sprinkler Watchman. DS1010. Excess Pressure Pump for Wet Pipe Sprinkler System. DS1011. Supervisory Switch. DS510. Relays, Uniform and Direct Current
History of automatic fire sprinklers
THE STORY OF THE INTRODUCTION TO ENGLAND OF THE AUTOMATIC SPRINKLER WRITTEN BY JOHN WORMALD IN DECEMBER 1923 ... HISTORY AUTOMATIC. FIRE SPRINKLERS. 1881 - 1888 ... to publish a short pamphlet on the subject of Automatic Sprinklers, it was not anticipated that the demand for copies ...
General Sprinkler Information & Resources
... Myth 4: "Sprinklers are designed to protect property, but ... with fire sprinklers compared to those without sprinklers.The combination of automatic sprinklers and early warning ...
Spraysafe Automatic Sprinklers at Kellysearch Business Directory
Buy products such as Compressor Sprinkler Systems, Fire Protection Equipment or Systems, Valves, Pressure Relief, Valves, Relief, Sprinklers, Residential, Fire Protection Equipment...
automatic lawn sprinklers
This automatic lawn sprinklers Web site provides a ton of useful information. ... Search Google: Other automatic lawn sprinklers Resources: ... And our automatic sprinklers operate quietly, because they're ... Automatic Lawn Sprinklers - Easy Watering ...
Wayne Automatic Fire Sprinklers - Commercial, Residential Fire Alarms, Security, Fire Protection, FM 200, Alarm ...
Wayne Automatic Fire Sprinklers for Fire Alarms, Security, Fire Protection, FM 200, Alarm Monitoring, fire Sprinklers ... and every employee at Wayne Automatic Fire Sprinklers. is a valued partner in caring about ... Copyright © 2002-04 Wayne Automatic Fire Sprinklers, Inc. Li. Nos: COA7523 • EF20000358 ...
NOTE: Please contact us right away
if you'd like to make any changes to your listing.
|
| | | |  |
|  |
|