Sprinklers
and Sprinkler Systems 
|
| |
|
| |
| |
| Welcome to magicsprinkler.com where you
can find all things related to the world of sprinklers,
sprinkler systems, and lawn care maintenance. Let's
face it, there are a lot of sites out there with a lot
of garbage about sprinklers and few with detail information
about what can make your sprinkler system run at an
optimized level. Are you curious about sprink lsystems,
or just want to learn how to be fix your own sprinklers?
Well then you've come to the right place at magicsprinkler.com |
| | |
|
| | | | |
The sprinkler family tree
02/07/12
Supplying water to sprinklers from more than one path has been used for generations.
There are three basic layouts for sprinkler systems. The original systems were
designed in a “tree” layout that supplied water through a cross
main, which acts like the trunk of a tree. (See Figure 2, page 46.) Sprinklers
are located on branch lines attached to the cross main, and the arrangement
resembles a tree.
The second layout is the “simple loop” system, where a second cross
main is added. (See Figure 3, page 46.) The extra cross main splits the water
supply into two paths to a flowing sprinkler. The increased hydraulic efficiency
allows the use of smaller-diameter cross mains and branch lines.
The third layout is used to increase hydraulic efficiency even more. It's the
gridded layout, where additional cross mains are used to form the grid pattern.
(See Figure 4.) All of the pipe sections are interconnected, so water flows
through each. The specific path depends on the location of the flowing sprinkler.
Compared to a simple loop system, the multiple paths compound the number of
loops, and thus the name compound loop system.
The H-inch multipurpose system is a form of a gridded system. (See Figure 5.)
The only difference is that the multipurpose system uses flexible nonmetallic
pipe that attaches to the multiport fitting at angles. Thus the pipe sections
travel in arcs instead of right angles like rigid pipe.
Unlike tree or simple loop systems, water flows through every pipe section
and sprinkler fitting in a multipurpose system each time a plumbing fixture
is opened. This offers two technical advantages:
1. The volume of water flowing in each pipe section is relatively small and
has a corresponding low velocity. This allows the system to supply the required
volume of water to sprinklers with a lower supply pressure.
2. The sprinkler system is constantly tested. Every time someone opens a plumbing
fixture, water flows through the entire system. If the plumbing is working,
so is the sprinkler system
| | | |
| |
Globe Fire Sprinkler Corporation
... Welcome to GLOBE FIRE SPRINKLER CORPORATION ...
residential sprinkler association
FSA Home Page See how Life Safety Fire Sprinkler systems can virtually eliminate fire deaths and reduce fire injuries and property damage by over 80%. ... The Fire Sprinkler Association ...
residential fire safety institute
The Home Fire Sprinkler Coalition
The Home Fire Sprinkler Coalition ...
Omega Fire Sprinklers Recalled by Central Sprinkler
... recall of approximately 8.4 million Omega brand fire sprinklers manufactured since 1982 by Central Sprinkler Corp ... Properly functioning fire sprinklers save lives when a fire occurs ...
NATIONAL FIRE SPRINKLER ASSOCIATION
NFPA Acts to Require Sprinklers in Dwellings ... aims to reduce home fire injuries and deaths by increasing the use of residential fire sprinklers. ... available a document titled "Residential Fire Sprinklers...A Step-by-Step Approach ...
Fire Busters Inc.
... installing all types of residential fire sprinklers including: concealed, pendents and sidewall sprinkler ... Fire sprinklers provide the latest and best life safety device for your ...
Fire Protection > Sprinklers in the Yahoo! Directory
Yahoo! reviewed these sites and found them related to Fire Protection > Sprinklers ... rosettes, headguards, fire bells and fire alarm system ... fire protection and suppression systems. Wiginton Fire Sprinklers, Inc. - designs, installs, and maintains fire ...
Automatic Commercial Fire Sprinkler System Contractor- Fire Sprinkler Design & Installation
... Today you will find Koetter Fire Protection systems wherever fire sprinklers are needed ... buildings, airports and prisons, Koetter Fire Protection protects every kind of facility ...
Star Fire Sprinklers Recalled by Mealane
... is voluntarily recalling up to 1 million "Star" brand fire sprinklers manufactured from 1961 through 1976 ... CPSC is continuing its ongoing investigation of fire sprinklers. ...
Fire Sprinkler Hydraulics Software
Hydronics Engineering - computer software for the design and hydraulic calculation of fire sprinkler systems. User-friendly MS-Windows data entry spreadsheets. NFPA-style Submittal Reports & Graphs. ... FIRE SPRINKLER HYDRAULIC CALCULATIONS AND HYDRANT FLOW TESTING ... for Commercial and Industrial fire sprinkler and spray systems per ... It keeps track of fire pump discharge and suction ...
FIRE SPRINKLERS, INC. - Home
... FIRE SPRINKLERS, INC. Licensed by the State of Missouri as a Professional Engineering Corporation; established in St ... FIRE SPRINKLERS, INC. was incorporated in 1994 in the City of ...
Rollins Fire Sprinklers
Fire sprinkler design and installation, modifications of existing systems, residential and commercial, service and maintenance. Serving Santa Cruz, Monterey and Santa Clara Counties. ... Rollins Fire Sprinklers, owned by Ron Rollins, is a family run business with 35 years of experience in plumbing and ... Rollins Fire Sprinklers. 802 Estate Dr. # ...
Home Fire Sprinkler Coalition
Home Fire Sprinkler Coalition ...
Wayne Automatic Fire Sprinklers - Commercial, Residential Fire Alarms, Security, Fire Protection, FM 200, Alarm ...
Wayne Automatic Fire Sprinklers for Fire Alarms, Security, Fire Protection, FM 200, Alarm Monitoring, fire Sprinklers ... and every employee at Wayne Automatic Fire Sprinklers. is a valued partner in caring about ... Copyright © 2002-04 Wayne Automatic Fire Sprinklers, Inc. Li. Nos: COA7523 • EF20000358 ...
General Sprinkler Information & Resources
... in the proper installation of fire sprinklers. Fire sprinklers should always be installed in ... using approved and/or listed materials. Fire sprinklers protect lives and property ...
Fire Sprinklers UK Ltd
Fire Sprinklers UK Ltd. for design, fabrication, installation, & maintenance of automatic sprinkler systems ... Van Road mailto:office@fire-sprinklers.co.uk ...
NFPA
... Reduce the worldwide burden of fire and other hazards on the quality of life by providing and advocating ... and 5000® set to require sprinklers in new 1- and 2-family ...
BlazeMaster & FlameGuard CPVC Plastic Residential, Domestic, Home or House Fire Sprinkler Systems
... continued my interest with residential fire sprinklers and then became involved with the CPVC fire sprinkler ... about using plastic pipe for fire sprinklers but as I studied the ...
American Fire Sprinkler Association
... officials have passed more stringent requirements for fire sprinklers in group homes ... your source for current information related to automatic fire sprinklers. AFSA Mission Statement ...
NOTE: Please contact us right away
if you'd like to make any changes to your listing.
|
| | | |  |
|  |
|